DC CHARACTERISTICS
VCC = 4.5 V to 5.5V @ 0°C to +70°C
Sym Parameter
Min Max
VCH
Clock Input High Voltage
VCL
Clock Input Low Voltage
VIH
Input High Voltage
VIL
Input Low Voltage
VRH
Reset Input High Voltage
VRL
Reset Input Low Voltage
V
Output High Voltage
OH
Output High Voltage
VOL
Output Low Voltage
I
Input Leakage
IL
IOL
Output Leakage
IIR
Reset Input Current
ICC
VCC Supply Current
3.8
VCC
–0.3 0.8
2.0
VCC
–0.3 0.8
3.8
VCC
–0.3 0.8
2.0
2.4
0.8
–10
10
–10
10
–50
50
Notes:
* Typical @ 25°C
1. A combined total of six I/O pins from Ports 2 and 3 may be used to sink
10 mA each at 0.8V VOL (max. three pins per port). These may be used
for LEDs or as general-purpose outputs requiring high sink current.
Z86E23
CPS DC-4060-06
Typ* Unit
V
V
V
V
V
V
V
V
V
µA
µA
µA
25 mA
Condition
Driven by External Clock Generator
Driven by External Clock Generator
I
OH
=
–250
µA
(Port
2
only)
IO H = –250 µA (Port 3 only)
IOL= +4.0 mA (See Note (1) below.)
V = 0V, 5.5V
IN
VIN = 0V, 5.5V
VIN = 0V, 5.5V
© 1994 by Zilog, Inc. All rights reserved. No part of this document
may be copied or reproduced in any form or by any means
without the prior written consent of Zilog, Inc. The information in
this document is subject to change without notice. Devices sold
by Zilog, Inc. are covered by warranty and patent indemnification
provisions appearing in Zilog, Inc. Terms and Conditions of Sale
only. Zilog, Inc. makes no warranty, express, statutory, implied or
by description, regarding the information set forth herein or
regarding the freedom of the described devices from intellectual
property infringement. Zilog, Inc. makes no warranty of mer-
chantability or fitness for any purpose. Zilog, Inc. shall not be
responsible for any errors that may appear in this document.
Zilog, Inc. makes no commitment to update or keep current the
information contained in this document.
Zilog’s products are not authorized for use as critical compo-
nents in life support devices or systems unless a specific written
agreement pertaining to such intended use is executed between
the customer and Zilog prior to use. Life support devices or
systems are those which are intended for surgical implantation
into the body, or which sustains life whose failure to perform,
when properly used in accordance with instructions for use
provided in the labeling, can be reasonably expected to result in
significant injury to the user.
Zilog, Inc. 210 East Hacienda Ave.
Campbell, CA 95008-6600
Telephone (408) 370-8000
Telex 910-338-7621
FAX 408 370-8056