EiceDRIVERTM SIL
1EDI2004AS
Protection and Diagnostics
3.3
Protection Functions: Category B
3.3.1 Power Supply Voltage Monitoring
The Power Supply Voltage Monitoring functionality is summarized in Table 22:
Table 22 Power Supply Voltage Monitoring Overview
Parameter
Short Description
Function
Periodicity
Monitoring of VCC1, VCC2, VEE2.
Continuous.
Action in case of failure event 1. Emergency (Regular) Turn-off Sequence.
2. Error Flag PER.RST1 (UVLO1) or SER.UVLO2ER or OVLO2ER or UVLO3ER or
OVLO3ER) is set.
3. Assertion of signal NRST/RDY (UVLO1 only) or NFLTB.
Programmability
Yes (OVLO2and OVLO3).
In-System Testability
Yes (see Chapter 3.5.8).
In order to ensure a correct switching of the IGBT, the device supports an undervoltage lockout (UVLO)
function for VCC1, VCC2, VEE2, and an overvoltage lockout (OVLO) function for VCC2 and VEE2 (Figure 21).
VCC2MAX
VOVLO 2
VUVLO 2H
VUVLO 2 L
OVLO2
Valid VCC2 range to
enable the device
UVLO2
VUVLO 1H
VUVLO 1 L
Valid VCC1 range to
enable the device
UVLO1
VEE2MAX (Max.)
VOVLO 3
VUVLO 3
VEE2MAX(Min.)
OVLO3
Valid VEE2 range to
enable the device
UVLO3
Figure 21 Power Supply Supervision Function
Data Sheet
61
Valid VCC2
operating range
Valid VCC1
operating range
Valid VEE2
operating range
Rev. 2.0
2019-01-16