IGBT Modules
7MBR10SA120
[ Inverter ]
Switching time vs. Collector current (typ.)
Vcc=600V, VGE=±15V, Rg=120Ω, Tj=25°C
1000
500
toff
ton
tr
100
tf
50
0
5000
1000
500
5
10
15
20
Collector current : Ic [ A ]
[ Inverter ]
Switching time vs. Gate resistance (typ.)
Vcc=600V, Ic=10A, VGE=±15V, Tj=25°C
ton
toff
tr
100
50
50
8
tf
100
500
1000
Gate resistance : Rg [ Ω ]
[ Inverter ]
Switching loss vs. Gate resistance (typ.)
Vcc=600V, Ic=10A, VGE=±15V, Tj=125°C
2000
Eon
6
4
2
Eoff
0
50
100
Err
500
1000
2000
Gate resistance : Rg [ Ω ]
[ Inverter ]
Switching time vs. Collector current (typ.)
Vcc=600V, VGE=±15V, Rg=120Ω, Tj=125°C
1000
toff
500
ton
tr
tf
100
50
0
5
10
15
20
Collector current : Ic [ A ]
[ Inverter ]
Switching loss vs. Collector current (typ.)
Vcc=600V, VGE=±15V, Rg=120Ω
3
Eon(125 oC)
2
Eon(25 oC)
Eoff(125 oC)
1
Eoff(25 oC)
Err(125 oC)
Err(25 oC)
0
0
5
10
15
20
Collector current : Ic [ A ]
[ Inverter ]
Reverse bias safe operating area
+VGE=15V, -VGE=<15V, Rg=>120Ω, T=j<125°C
25
20
15
10
5
0
0
200
400
600
800
1000
1200
1400
Collector - Emitter voltage : VCE [ V ]