ACT8810
Rev 9, 15-Nov-12
RTC LOW-DROPOUT LINEAR REGULATOR
REGISTER DESCRIPTIONS
Note: See Table 1 for default register settings.
Table 16:
REG6 Control Register Map
ADDRESS
D7
D6
D5
42h
R
R
R
R: Read-Only bits. Default Values May Vary.
Table 17:
REG6 Control Register Bit Descriptions
ADDRESS NAME BIT ACCESS
42h
VSET6 [4:0]
R/W
42h
[7:5]
R
DATA
D4
D3
D2
D1
D0
VSET6
FUNCTION
REG6 Output Voltage
Selection
DESCRIPTION
See Table 18
READ ONLY
Table 18:
REG6/VSETx[ ] Output Voltage Setting
REG6CFG/VSETx[4:3]
REG6CFG/VSETx[2:0]
00
01
10
11
000
0.90
1.45
1.90
2.75
001
1.00
1.50
2.00
2.80
010
1.10
1.55
2.10
2.85
011
1.20
1.60
2.20
2.90
100
1.25
1.70
2.40
3.00
101
1.30
1.75
2.50
3.10
110
1.35
1.80
2.60
3.20
111
1.40
1.85
2.70
3.30
Innovative PowerTM
ActivePMUTM and ActivePathTM are trademarks of Active-Semi.
I2CTM is a trademark of NXP.
- 38 -
www.active-semi.com
Copyright © 2012 Active-Semi, Inc.