ASAHI KASEI
[AK4516A]
Mode Control 1
Addr
Register Name
D7
D6
D5
D4
D3
D2
D1
D0
01H Mode Control 1
0
0
0
0
PM3 PM2 PM1 PM0
R/W
R/W
RESET
0
0
0
0
0
1
1
1
PM3-0: Power Management (0: Power Down, 1:Power Up)
PM0: Mixer, PGA input, Auto Limitter and Auto Recovery power control.
PM1: Power control of ADC
PM2: Power control of DAC
PM3: Used both as power control of analog loopback circuit and as selection of MUX.
(0: DAC, 1:Analog loopback)
PM0-3 can be partially powered-down by ON/OFF of PM0-3. When PD pin goes "L",
all the circuit in AK4516A can be powered-down regardless of PM0-3.
When PM0-3 go all "0", all the circuits in AK4516A can be also powered-down.
When PM3 goes "1", input for output-AMP is selected to analog loopback circuit from
DAC output.
Output MUX and AMP are powered-down when PD="L" or PM2=PM3="0". Refer to
Figure 11 .
The loopback output and the MUX selecting DAC output is a MIXER with the switch in
practice. Therefore, when both PM2 and PM3 select ON, the analog loopback signal
and DAC output are mixed by Gain 1.
Except the case of PM0=PM1=PM2=PM3="0" or PD pin="L", MCLK, BCLK, LRCK
should not be stopped.
When the input PGA and MUX are powered-down by PM0-3 or PD pin, the output of
AMP becomes Hi-Z(floating).
This register is reset by the PD pin="L", then inhibits writing to this register.
M0026-E-00
- 22 -
1998/08