Figure 14. Output Acknowledge
SCL
1
AT88SC153
8
9
DATA IN
DATA OUT
Note:
START
ACKNOWLEDGE
To transmit a NACK (no acknowledge), hold data (SDA) high during the entire ninth clock
cycle.
Absolute Maximum Ratings
Operating Temperature: −55°C to +125°C
Storage Temperature: −65°C to +150°C
Voltage on Any Pin with Respect to Ground: −0.7V to
VCC + 0.7V
Maximum Operating Voltage: 6.25V
DC Output Current: 5.0 mA
NOTICE:
Stresses beyond those listed under “Absolute
Maximum Ratings” may cause permanent dam-
age to the device. This is a stress rating only;
functional operation of the device at these or any
other conditions beyond those indicated in the
operational sections of this specification is not
implied. Exposure to absolute maximum rating
conditions for extended periods may affect
device reliability
15
1016D–SMEM–04/04