Qdatasheet_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

C8051T602 View Datasheet(PDF) - Silicon Laboratories

Part Name
Description
MFG CO.
C8051T602
Silabs
Silicon Laboratories Silabs
'C8051T602' PDF : 168 Pages View PDF
C8051T600/1/2/3/4/5/6
Table 23.1. SMBus Clock Source Selection
SMBCS1
0
0
1
1
SMBCS0
0
1
0
1
SMBus Clock Source
Timer 0 Overflow
Timer 1 Overflow
Timer 2 High Byte Overflow
Timer 2 Low Byte Overflow
The SMBCS1–0 bits select the SMBus clock source, which is used only when operating as a master or
when the Free Timeout detection is enabled. When operating as a master, overflows from the selected
source determine the absolute minimum SCL low and high times as defined in Equation 23.1. Note that the
selected clock source may be shared by other peripherals so long as the timer is left running at all times.
For example, Timer 1 overflows may generate the SMBus and UART baud rates simultaneously. Timer
configuration is covered in Section “25. Timers” on page 145.
THighMin
=
TLowMin
=
----------------------1-----------------------
fClockSourceOverflow
Equation 23.1. Minimum SCL High and Low Times
The selected clock source should be configured to establish the minimum SCL High and Low times as per
Equation 23.1. When the interface is operating as a master (and SCL is not driven or extended by any
other devices on the bus), the typical SMBus bit rate is approximated by Equation 23.2.
BitRate = -f-C----l-o---c--k--S---o--u---r--c--e--O----v--e--r--f--l-o---w-
3
Equation 23.2. Typical SMBus Bit Rate
Figure 23.4 shows the typical SCL generation described by Equation 23.2. Notice that THIGH is typically
twice as large as TLOW. The actual SCL output may vary due to other devices on the bus (SCL may be
extended low by slower slave devices, or driven low by contending master devices). The bit rate when
operating as a master will never exceed the limits defined by Equation 23.1.
Timer Source
Overflows
SCL
TLow
THigh
SCL High Timeout
Figure 23.4. Typical SMBus SCL Generation
Setting the EXTHOLD bit extends the minimum setup and hold times for the SDA line. The minimum SDA
setup time defines the absolute minimum time that SDA is stable before SCL transitions from low-to-high.
The minimum SDA hold time defines the absolute minimum time that the current SDA value remains stable
124