Qdatasheet_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

C8051T602 View Datasheet(PDF) - Silicon Laboratories

Part Name
Description
MFG CO.
C8051T602
Silabs
Silicon Laboratories Silabs
'C8051T602' PDF : 168 Pages View PDF
C8051T600/1/2/3/4/5/6
Bit
MASTER
TXMODE
STA
STO
ACKRQ
ARBLOST
ACK
SI
Table 23.3. Sources for Hardware Changes to SMB0CN
Set by Hardware When:
A START is generated.
START is generated.
SMB0DAT is written before the start of an
SMBus frame.
A START followed by an address byte is
received.
A STOP is detected while addressed as a
slave.
Arbitration is lost due to a detected STOP.
A byte has been received and an ACK
response value is needed (only when
hardware ACK is not enabled).
A repeated START is detected as a
MASTER when STA is low (unwanted
repeated START).
SCL is sensed low while attempting to
generate a STOP or repeated START
condition.
SDA is sensed low while transmitting a 1
(excluding ACK bits).
The incoming ACK value is low
(ACKNOWLEDGE).
A START has been generated.
Lost arbitration.
A byte has been transmitted and an
ACK/NACK received.
A byte has been received.
A START or repeated START followed by a
slave address + R/W has been received.
A STOP has been received.
Cleared by Hardware When:
A STOP is generated.
Arbitration is lost.
A START is detected.
Arbitration is lost.
SMB0DAT is not written before the
start of an SMBus frame.
Must be cleared by software.
A pending STOP is generated.
After each ACK cycle.
Each time SI is cleared.
The incoming ACK value is high
(NOT ACKNOWLEDGE).
Must be cleared by software.
Rev. 1.2
129