CC1110Fx / CC1111Fx
7.12 SPI AC Characteristics
TA = 25 °C, VDD = 3.0V if nothing else stated. All measurement results are obtained using the
CC1110EM reference designs ([1]).
Parameter
Min
Typ
Max
Unit Condition/Note
SCK period
SCK duty cycle
SSN low to SCK
SCK to SSN high
MISO setup
MISO hold
SCK to MOSI
SCK period
SCK duty cycle
MOSI setup
MOSI hold
SCK to MISO
2·tSYSCLK
30
10
10
100
10
10
See
section
13.14.3
ns
Master. See item 1, Figure 5
50
%
Master.
See item 5, Figure 5
ns
See item 6, Figure 5
ns
Master. See item 2, Figure 5
ns
Master. See item 3, Figure 5
25
ns
Master. See item 4, Figure 5, load = 10 pF
ns
Slave. See item 1, Figure 5
50
%
Slave.
ns
Slave. See item 2, Figure 5
ns
Slave. See item 3, Figure 5
25
ns
Slave. See item 4, Figure 5, load = 10 pF
Table 20: SPI AC Characteristics
Figure 5: SPI AC Characteristics
SWRS033E
Page 26 of 239