ADG884
ABSOLUTE MAXIMUM RATINGS
TA = 25°C, unless otherwise noted.
Table 5.
Parameter
VDD to GND
Analog Inputs1
Digital Inputs1
Peak Current, S or D
5 V Operation
Continuous Current, S or D
5 V Operation
Operating Temperature Range
Industrial (B Version)
Storage Temperature Range
Junction Temperature
10-Lead MSOP Package
θJA Thermal Impedance
θJC Thermal Impedance
10-Lead WLCSP Package
(4-Layer Board)
θJA Thermal Impedance
10-Lead LFCSP Package
(4-Layer Board)
θJA Thermal Impedance
θJC Thermal Impedance
IR Reflow, Peak Temperature <20 s
Rating
−0.3 V to +6 V
−0.3 V to VDD + 0.3 V
−0.3 V to 6 V or 10 mA
(whichever occurs first)
600 mA (pulsed at
1 ms, 10% duty cycle max)
400 mA
−40°C to +85°C
−65°C to +150°C
150°C
206°C/W
44°C/W
120°C/W
76°C/W
13.5°C/W
235°C
1 Overvoltages at IN, S, or D are clamped by internal diodes. Current should be
limited to the maximum ratings given.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Only one absolute maximum rating may be applied at any one
time.
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the
human body and test equipment and can discharge without detection. Although this product features
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance
degradation or loss of functionality.