Figure 4 - Equivalent Input Circuit
VCC
Q3
C IN
1PF
RIN
V IN
100Ω
RIN
V IN
100Ω
VR2
VR1
VEE
R1
C IN
1PF
Q1
Q4
R2
Q7
Q5
Q2
Q6
Q8
R3
R4
R5
Figure 7 - AC Test Fixture
V+
IN
MONITOR
VCC
(+5.0V)
V+
IN
V-
IN
15 µF
6
L1
15 µF
6
SEMI
RIGID
6
SEMI
RIGID
16.7 Ω
L2
16.7 Ω
16.7 Ω
+
V+
Q
50 Ω DUT 4
Q
-
V-
LE
50 Ω
50 Ω
16.7 Ω
L2
L1
16.7 Ω
16.7 Ω
0.1 µF
100 Ω
0.1 µF
6
6
Figure 5 - Output Circuit
Q Output
Q 23
R7
240 Ω
V1
Q
21
R8
240 Ω
Q 24
Q 22
V2
4.5 mA
Q Output
Figure 6 - Test Load
Rz
50 Ω
RL
100 Ω
Vpd
(-4.0 V)
L3
50 Ω Coax
RZ
100 Ω
NOTES: 1. ALL BNC & SEMIRIGID COAX SHIELD ARE
GROUNDED.
2. ALL RESISTORS 1% (10 Ω = 49.9 Ω).
3. KEEP ALL LEADS AS SHORT AS POSSIBLE
WITH ELECTRICAL LENGTHS L1 = L2 + L3.
4. D.U.T. PLUGS INTO A 16 PIN HIGH
FREQUENCY PIN SOCKET.
5. MONITOR INPUT IMPEDANCE 50 Ω TO GND.
6. SEMIRIGID COAX SHIELD SHOULD BE
CONNECTED AS CLOSE TO THE DEVICE AS
POSSIBLE.
SPT
HCMP96850
6
3/18/97