ICS1893CY-10 Data Sheet - Release
Chapter 9 DC and AC Operating Conditions
9.5.4 100M MII / 100M Stream Interface: Synchronous Transmit Timing
Table 9-11 lists the significant time periods for the 100M MII / 100M Stream Interface synchronous transmit
timing. The time periods consist of timings of signals on the following pins:
• TXCLK
• TXD[3:0]
• TXEN
• TXER
Figure 9-5 shows the timing diagram for the time periods.
Table 9-11. 100M MII / 100M Stream Interface: Synchronous Transmit Timing
Time
Period
Parameter
t1 TXD[3:0], TXEN, TXER Setup to TXCLK Rise
t2 TXD[3:0], TXEN, TXER Hold after TXCLK Rise
Conditions
–
–
Min.
15
0
Typ.
–
–
Max. Units
–
ns
–
ns
Figure 9-5. 100M MII / 100M Stream Interface Synchronous Transmit Timing Diagram
TXCLK
TXD[3:0]
TXEN
TXER
t1
t2