L6208Q
Circuit description
Figure 24. tDELAY vs. CEN (VDD = 5 V)
5.10
&(1 >Q)@
$0
Thermal protection
In addition to the overcurrent detection, the L6208Q device integrates a thermal protection
to prevent device destruction in the case of junction over temperature. It works sensing the
die temperature by means of a sensitive element integrated in the die. The device switches
off when the junction temperature reaches 165 °C (typ. value) with 15 °C hysteresis (typ.
value).