L9484
Table 5.
Symbol
Electrical characteristcs (continued)
(Tcase = -35°C to +150°C continuous unless otherwise specified)
Parameter
Test condition
Min. Typ. Max. Unit
VLR Load regulation
VSR Speed regulation
6500 grpm, 10% to 95% load
15A load, 2000 to 20,000
grpm
300 mV
100 mV
VF-ON Output saturation voltage
IF = 6A, VGO = 14.0V, Tcase =
25C
750 mV
VF-ON Output saturation voltage
IF = 5A, VGO = 13.5V, Tcase =
125C
850 mV
IF-LIM Field limit current(1)
Current F+ Terminal to Gnd.
9.0
@ Tcase 25C
A
IF-LIM Field limit current(1)
Current F+ Terminal to Gnd.
6.0
@ Tcase = +150C
A
IG-MIN
Min. generator current load
Current measured @
generator output
0.5
A
VD-F Field discharge diode
IF = 6A, Tcase = 25C
1.85 V
ID-R Diode reverse current
VR = 20V
1 mA
FOSC oscillation frequency
During LRC operation
340 400 460 Hz
VDF DF saturation voltage
IDF 10mA
0.8 V
IDF-LK DF output leakage current VDF < 25V
10 A
FTURBO Internal clock frequency
VDF = 32 - 35V; thru 2.2k
4X
Hz
FTURBO IRD, SS, LRC rate
VDF = 32 - 35V; thru 2.2k
16
1. The Field Drive capability shall not decrease as a function of temperature between 25°C and 150°C, at a
rate faster than -0.024A/°C (for example, Field Drive shall be capable of 7.2A at 100°C).
Figure 2. Typical application schematic
NTC
7
4
1
8
2
6
3
5/11