L9484
Table 8.
Symbol
Regulation features (continued)
Parameter
Conditions
Min. Typ. Max. Unit
VP-F
Phase input voltage low fault
threshold
IP
Phase terminal current sink
FP-IR
FP-TR
Initiate regulation phase
frequency
Terminate regulation phase
frequency
IRD Initiate regulation delay
FSDC Field strobe duty cycle
LRC Load response control rate
FP-LRC LRC transition frequency
SS Soft-start
VP > 1.5V and < 12.6V
VGO = 12.6V
7.0
8
9.0
V
0.3
3.5 mA
123 145 167 Hz
59
72
86
Hz
Regulator activated, VP-IR AND
FP-IR conditions met first time.
1.7
2
2.3
s
Regulator activated and
(regulation terminated or
regulation not initiated)
16 18.75 22
%
Field drive duty cycle increase
34
40
46 %/s
LRC enabled if FP < FP-LRC
255 300 345 Hz
LRC enabled until VSP reached
regardless other conditions
34
40
46 %/s