SK BIT
VALUE
0
0
1
1
Table 20 - Skip Bit vs Read Data Command
DATA ADDRESS
MARK TYPE
RESULTS
ENCOUNTERED
SECTOR CM BIT OF DESCRIPTION OF
READ? ST2 SET?
RESULTS
Normal Data
Yes
No
Normal
termination.
Deleted Data
Yes
Yes
Address not
incremented. Next
sector not
searched for.
Normal Data
Yes
No
Normal
termination.
Deleted Data
No
Yes
Normal
termination.
Sector not read
("skipped").
Read Deleted Data
This command is the same as the Read Data command, only it operates on sectors that contain a Deleted Data Address
Mark at the beginning of a Data Field.
Table 21 describes the effect of the SK bit on the Read Deleted Data command execution and results.
Except where noted in Table 21, the C or R value of the sector address is automatically incremented (see Table 22).
SK BIT
VALUE
0
0
1
1
Table 21 - Skip Bit vs. Read Deleted Data Command
DATA ADDRESS
MARK TYPE
RESULTS
ENCOUNTERED
SECTOR CM BIT OF DESCRIPTION OF
READ? ST2 SET?
RESULTS
Normal Data
Yes
Yes
Address not
incremented. Next
sector not
searched for.
Deleted Data
Yes
No
Normal
termination.
Normal Data
No
Yes
Normal
termination.
Sector not read
("skipped").
Deleted Data
Yes
No
Normal
termination.
Read A Track
This command is similar to the Read Data command except that the entire data field is read continuously from each of
the sectors of a track. Immediately after encountering a pulse on the nINDEX pin, the FDC starts to read all data fields
on the track as continuous blocks of data without regard to logical sector numbers. If the FDC finds an error in the ID or
DATA CRC check bytes, it continues to read data from the track and sets the appropriate error bits at the end of the
command. The FDC compares the ID information read from each sector with the specified value in the command and
sets the ND flag of Status Register 1 to a “1” if there no comparison. Multi-track or skip operations are not allowed with
this command. The MT and SK bits (bits D7 and D5 of the first command byte respectively) should always be set to "0".
This command terminates when the EOT specified number of sectors has not been read. If the FDC does not find an ID
Address Mark on the diskette after the second occurrence of a pulse on the nINDEX pin, then it sets the IC code in
Status Register 0 to "01" (abnormal termination), sets the MA bit in Status Register 1 to "1", and terminates the
command.
SMSC LPC47B27x
- 45 -
DATASHEET
Rev. 04-17-07