LTC6803-2/LTC6803-4
OPERATION
Start Cell Voltage ADC Conversions and Poll Status (Broadcast Command with Toggle Polling)
1. Pull CSBI low
2. Send STCVAD command and its PEC byte (all devices in stack start ADC conversions simultaneously)
3. SDO output of all devices in parallel pulled low for approximately 12ms
4. SDO output toggles at 1kHz rate, indicating conversions complete for all devices
5. Pull CSBI high to exit polling
Poll Interrupt Status (Level Polling)
1. Pull CSBI low
2. Send Address and PEC bytes for bottom device
3. Send PLINT command and PEC bytes
4. SDO output from bottom device pulled low if any device has an interrupt condition; otherwise, SDO high
5. Pull CSBI high to exit polling
6. Repeat steps 1-5 for middle device and top device
CSBI
SCKI
SDI
Sn
(n = 1 TO 12)
WRCFG + CFGR + PEC
td td < 2µs IF Sn IS UNLOADED
Sn, DISCHARGE PIN STATE
680324 F07
Figure 7. S Pin Action and SPI Transmission
680324f
27