DC and AC parameters
M24512-x, M24256-Bx
Table 15. DC characteristics (M24256-BF)(1)
Symbol
Parameter
Test condition (in addition to
those in Table 9)
Min.
Max. Unit
ILI
Input leakage current
(E1, E2, SCL, SDA)
VIN = VSS or VCC
device in Standby mode
±2
µA
ILO Output leakage current
SDA in Hi-Z, external voltage
applied on SDA: VSS or VCC
VCC = 1.7 V, fc= 400 kHz
(rise/fall time < 50 ns)
±2
µA
0.8
mA
ICC Supply current (Read)
ICC0 Supply current (Write)
ICC1 Standby supply current
VIL
Input low voltage
(SCL, SDA, WC)
VIH
Input high voltage
(SCL, SDA, WC)
VOL Output low voltage
VCC = 2.5 V, fc= 400 kHz
(rise/fall time < 50 ns)
1
mA
VCC = 5.0 V, fc= 400 kHz
(rise/fall time < 50 ns)
2
mA
1.7 V < VCC < 5.5 V, fc= 1 MHz(2)
(rise/fall time < 50 ns)
2.5
mA
During tW, 1.7 V < VCC < 5.5 V
Device not selected(4),
VIN = VSS or VCC, VCC = 1.7 V
Device not selected(4),
VIN = VSS or VCC, VCC = 2.5 V
Device not selected(4),
VIN = VSS or VCC, VCC = 5.5 V
5(3)
mA
1
µA
2
µA
3
µA
1.7 V ≤ VCC < 2.5 V
–0.45 0.25 VCC V
2.5 V ≤ VCC ≤ 5.5 V
–0.45 0.3 VCC
1.7 V ≤ VCC < 2.5 V
0.75VCC VCC+1 V
2.5 V ≤ VCC ≤ 5.5 V
0.7VCC VCC+1
IOL = 1 mA, VCC = 1.7 V
0.2
V
IOL = 2.1 mA, VCC = 2.5 V
0.4
V
IOL = 3.0 mA, VCC = 5.5 V
0.4
V
1. Preliminary data.
2. Only for M24xxx-HR6.
3. Characterized value, not tested in production.
4. The device is not selected after power-up, after a READ command (after the Stop condition), or after the
completion of the internal write cycle tW (tW is triggered by the correct decoding of a WRITE command).
24/37