DC and AC parameters
M24C16-125 M24C08-125 M24C04-125 M24C02-125
6
DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristic tables that
follow are derived from tests performed under the measurement conditions summarized in
the relevant tables. Designers should check that the operating conditions in their circuit
match the measurement conditions when relying on the quoted parameters.
Table 5. Operating conditions
Symbol
Parameter
VCC Supply voltage
Ambient operating temperature
Min.
2.5
–40
Max.
Unit
5.5
V
125
°C
Table 6. AC measurement conditions
Symbol
Parameter
Cbus
Load capacitance
SCL input rise/fall time, SDA input fall time
Input levels
Input and output timing reference levels
Min.
Max.
100
-
50
0.2 VCC to 0.8 VCC
0.3 VCC to 0.7 VCC
Unit
pF
ns
V
V
Figure 10. AC measurement I/O waveform
)NPUT VOLTAGE LEVELS
6##
6##
)NPUT AND OUTPUT
TIMING REFERENCE LEVELS
6##
6##
Table 7. Input parameters
Symbol
Parameter(1)
CIN
CIN
ZWCL
ZWCH
tNS
Input capacitance (SDA)
Input capacitance (other pins)
WC input impedance
WC input impedance
Pulse width ignored (input filter on
SCL and SDA)
1. Characterized only.
Test condition
VIN < 0.3 V
VIN > 0.7VCC
Single glitch
!)#
Min.
Max.
Unit
-
8
pF
-
6
pF
15
70
kΩ
500
-
kΩ
-
100
ns
20/30