M24C02-A125
8
DC and AC parameters
DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device.
Table 6. Operating conditions (voltage range R)
Symbol
Parameter
Min.
Max.
Unit
VCC
Supply voltage
TA
Ambient operating temperature
1.7
5.5
V
–40
125
°C
Symbol
Cbus
-
-
-
Table 7. AC measurement conditions
Parameter
Min.
Max.
Load capacitance
100
SCL input rise/fall time, SDA input fall time
-
50
Input levels
Input and output timing reference levels
0.2 VCC to 0.8 VCC
0.3 VCC to 0.7 VCC
Figure 9. AC measurement I/O waveform
)NPUT VOLTAGE LEVELS
6##
6##
)NPUT AND OUTPUT
4IMING REFERENCE LEVELS
6##
6##
Unit
pF
ns
V
V
-36
DocID025755 Rev 5
25/40
39