DC and AC parameters
10 DC and AC parameters
M25PX32
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC Characteristic tables that
follow are derived from tests performed under the measurement conditions summarized in
the relevant tables. Designers should check that the operating conditions in their circuit
match the measurement conditions when relying on the quoted parameters.
Table 13. Operating conditions
Symbol
Parameter
VCC
VPPH
TA
TAVPP
Supply voltage
Supply voltage on VPP pin for Fast Bulk Erase mode
Ambient operating temperature
Ambient operating temperature for Fast Bulk Erase
mode
Min.
2.7
8.5
–40
Typ.
Max. Unit
3.6 V
9.5 V
85 °C
15
25
35 °C
Table 14. AC measurement conditions
Symbol
Parameter
Min.
Max.
Unit
CL
Load capacitance
Input rise and fall times
30
pF
5
ns
Input pulse voltages
Input timing reference voltages
Output timing reference voltages
0.2VCC to 0.8VCC
V
0.3VCC to 0.7VCC
V
VCC / 2
V
1. Output Hi-Z is defined as the point where data out is no longer driven.
Figure 29. AC measurement I/O waveform
Input levels
0.8VCC
0.2VCC
Input and output
timing reference levels
0.7VCC
0.5VCC
0.3VCC
AI07455
Table 15. Capacitance(1)
Symbol
Parameter
Test condition
CIN/OUT Input/output capacitance (DQ0/DQ1)
VOUT = 0 V
CIN Input capacitance (other pins)
VIN = 0 V
1. Sampled only, not 100% tested, at TA=25 °C and a frequency of 20 MHz.
Min. Max. Unit
8
pF
6
pF