MX919B PRELIMINARY INFORMATION
2. Any ac coupling at the receive input will transform any step in the voltage at the discriminator output to a
slowly decaying pulse which can confuse the modem's level measuring circuits. As illustrated in Figure 25
below, the time for this step to decay to 37% of its original value is 'RC' where:
RC
=
2π(3dB
cut
-
off
1
frequency
of
the
RC network)
which is 32ms, or 153 symbol times at 4800 symbols/sec (9600bps) for a 5Hz network.
Step Input
to RC Circuit
Output of
RC Circuit
100%
37%
T = RC
Figure 25: Decay Time - AC Coupling
In general, it is best to DC couple the receiver discriminator to the modem and ensure that any AC coupling to
the transmitter's frequency modulator has a -3dB cut-off frequency of no higher than 5Hz for 4800
symbols/sec (9600bps).
©2001 MX•COM, INC.
www.mxcom.com Tele: 800 638 5577 336 744 5050 Fax: 336 744 5054
Doc. # 20480170.003
4800 Bethania Station Road, Winston-Salem, NC 27105-1201 USA All trademarks and service marks are held by their respective companies.