Using Pro-Motion
3.2.4 Step #2: Initialize Signal Sensing
This step of the axis setup wizard is used to select the signal sense parameters. Users should check the
invert sense checkbox in the first column for any input signals which are active low.
3.2.5 Step #3: Initialize Encoders
This step of the axis setup wizard is used to select the axis encoder parameters. If the current axis does
not have an encoder, set the encoder source setting to ‘none’ and click ‘next’ to continue.
Set the encoder source setting based on the axis encoder type. For axes that use an incremental quadra-
ture encoder (differential or non-differential) select incremental. For axes that have a resolver or absolute encoder,
select parallel.
The capture source setting controls high speed position capture. It can either be set to home which
triggers when the home switch is triggered, or index which triggers on the encoder’s index pulse.