PKS603-607
Parameter
Conditions
Symbol
SOURCE = 0 V; TJ = -40 to 125 °C
See Figure 18
Min
Typ
Max Units
(Unless Otherwise Specified)
OUTPUT (cont.)
Auto-Restart
ON Time
tAR
TJ = 25 °C
See Note J
30
ms
Auto-Restart
OFF Time
tAROFF
See Note K
5
s
NOTES:
A. Total current consumption is the sum of IS1 and IDSS when EN/UV pin is shorted to ground (MOSFET not
switching) and the sum of IS2 and IDSS when EN/UV pin is open (MOSFET switching).
B. Since the output MOSFET is switching, it is difficult to isolate the switching current from the supply current at the
DRAIN. An alternative is to measure the BYPASS pin current at 6.1 V.
C. See Typical Performance Characteristics section for BYPASS pin startup charging waveform.
D. BYPASS pin is externally supplied (bias winding).
E. For current limit at other di/dt values, refer to Figure 25.
F. This parameter is derived from characterization.
G. This parameter is derived from the change in current limit measured at 1X and 4X of the di/dt shown in the ILIMIT
specification.
H. IDSS1 is the worst case OFF state leakage specification at 80% of BVDSS and maximum operating junction
temperature. IDSS2 is a typical specification under worst case application conditions (rectified 265 VAC) for no-load
consumption calculations.
I. Breakdown voltage may be checked against minimum BVDSS specification by ramping the DRAIN pin voltage up
to but not exceeding minimum BVDSS.
J. Auto-restart on time has the same temperature characteristics as the oscillator (inversely proportional to
frequency). Auto-restart on time is extended during startup and certain fault conditions because the controller
reduces its oscillator clock frequency to prevent excessive drain currents. If excessive drain currents are still
occuring half way through the auto-restart on time, output MOSFET switching is disabled for the remainder of that
auto-restart on time episode (if the line is not sensed) or the supply latches off (if the line is sensed and adequate
line voltage is present).
K. Only applicable if no UV resistor is present at the EN/UV pin. 5 s applies only if the preceding switching auto-
restart event did not result in EN/UV pin going low. In that event, the first auto-restart off-time is 150 ms.