STPS160H100TV
THERMAL RESISTANCES
Symbol
Rth (j-c) Junction to case
Rth (c)
Parameter
Per leg
Total
Coupling
Value
0.9
0.5
0.14
Unit
°C/W
°C/W
°C/W
When the diodes 1 and 2 are used simultaneously :
∆ Tj(diode 1) = P(diode1) x Rth(j-c)(Per diode) + P(diode 2) x Rth(c)
STATIC ELECTRICAL CHARACTERISTICS (per diode)
Symbol
IR *
VF**
Parameter
Reverse leakage Current
Forward Voltage drop
Tests Conditions
Tj = 25°C
VR = VRRM
Tj = 125°C
Tj = 25°C
IF = 60 A
Tj = 125°C IF = 60 A
Tj = 25°C
IF = 80 A
Tj = 125°C IF = 80 A
Tj = 25°C
IF = 120 A
Tj = 125°C IF = 120 A
Tj = 25°C
IF = 160 A
Tj = 125°C IF = 160 A
Pulse test : * tp = 5 ms, δ < 2%
** tp = 380 µs, δ < 2%
To evaluate the conduction losses use the following equation :
P = 0.56 x IF(AV) + 0.0015 x IF2(RMS)
Min. Typ. Max. Unit
40
µA
13 50 mA
0.75
V
0.59 0.63
0.80
0.63 0.68
0.87
0.69 0.74
0.92
0.75 0.80
2/5