TDA9109A
Symbol
Parameter
BREATHING COMPENSATION
BRRANG
DC Breathing Voltage Range
(See 14)
BRADj
Vertical Output Variation versus DC
Breathing Control (Pin 23)
Test Conditions
V18
V18 > VREF-V
1V<V18< VREF-V
Min. Typ. Max. Units
1
12
V
0
%/V
-2.5
%/V
Note: 10 These parameters are not tested on each unit. They are measured during our internal qualification procedure.
Note: 11 With Register 07 at Byte 0xxxxxxx (S correction is inhibited) and Register 08 at Byte 0xxxxxxx (C correction
is inhibited), the vertical sawtooth has a linear shape.
Note: 12 This is the frequency range for which the vertical oscillator will automatically synchronize, using a single
capacitor value on Pin22 and Pin 20, and with a constant ramp amplitude.
Note: 13 TV is the vertical period.
Note: 14 When not used, the DC breathing control pin must be connected to 12V.
14/47