AC Operating Test Conditions (TA = 0 to 70°C, Voltage referenced to VSS = 0V)
Parameter
Value
Reference Voltage
Termination Voltage
AC Input High Level Voltage (VIH, min)
AC Input Low Level Voltage (VIL, max)
Input Timing Measurement Reference Level Voltage
Output Timing Measurement Reference Level Voltage
Input Signal maximum peak swing
VDDQ x 0.5
VDDQ x 0.5
VREF + 0.31
VREF - 0.31
VREF
VTT
1.5
Input minimum Signal Slew Rate
1
Termination Resistor (RT)
50
Series Resistor (RS)
25
Output Load Capacitance for Access Time Measurement (CL)
30
Unit
V
V
V
V
V
V
V
V/ns
Ohm
Ohm
pF
Output
Vtt=0.5*VDDQ
RT=50Ω
Z0=50Ω
CLOAD=30pF
VREF
=0.5*VDDQ
Output Load Circuit (SSTL_2)
Input/Output Capacitance
(VDD = 2.5V, VDDQ = 2.5V, TA = 25°C, f = 1MHz)
Parameter
Symbol
Min
Input capacitance (A0 ~ A11, BA0 ~ BA1, RAS, CAS, WE)
CIN1
36
Input capacitance (CKE0)
CIN2
36
Input capacitance (CS0)
CIN3
34
Input capacitance (CLK1, CLK2)
CIN4
34
Data & DQS input/output capacitance (DQ0~DQ63)
COUT
8
Input capacitance (DM0~DM8)
CIN5
8
Max
45
45
42
38
9
9
Unit
pF
pF
pF
pF
pF
pF
V826632G24S Rev. 1.1 July 2002
8