AC206
Preliminary Data Sheet
07/08/02
PHY STATUS REGISTER
Table 23: PHY Status Register 1
Bit
1.15
1.14
1.13
1.12
1.11
1.10:6
1.5
1.4
1.3
1.2
1.1
1.0
Name
100BASE-T4
100BASE-TX
Full-duplex
100BASE-TX
Half-duplex
10BASE-T Full-
duplex
10BASE-T Half-
duplex
Reserved
Auto-Negotiate
Complete
Remote Fault
Auto-Negotiate
Ability
Link Status
Jabber Detect
Extended
Capability
Definition
Tied to 0 indicates no 100BASE-T4 capability.
Tied to 0 indicates no 100BASE-TX full-duplex support.
Mode
RO
RO
1 = 100BASE-TX with half-duplex.
RO
0 = No TX half-duplex ability.
Tied to 0 indicates no 10BASE-T full-duplex support.
RO
1 = 10BASE-T with half-duplex.
0 = No 10BASE-T half-duplex ability.
1 = Auto-negotiate process completed, indicates Reg. 4, 5, 6 are
valid.
0 = Auto-negotiate process not completed.
1 = Remote fault condition detected.
0 = No remote fault.
After this bit is set, it remains set until it is cleared by reading
register 1 via MDC/MDIO interface.
1 = Able to perform auto-negotiation function, its value is
determined by ANEGA pin.
0 = Unable to perform auto-negotiation function.
1 = Link is established. If AC206 link fails, this bit becomes
cleared and remains cleared until register is read via MDC/MDIO
interface.
0 = Link is down, or has been dropped.
1 = Jabber condition detect.
0 = No Jabber condition detected.
1 = Extended register capable. This bit is tied permanently to
one.
RO
RO
RO
SC/LH
RO
SC/LL
SC/LH
RO
Default
0
0
1
0
1
00001
N/A
N/A
1
0
0
1
PHY IDENTIFIER 1 REGISTER
Table 24: PHY Identifier 1 Register
Register
Bit
Name
2.15:0 OUI*
Description
Assigned to the third through eighteenth bits of the Organizationally
Unique Identifier (OUI).
Mode
RO
Default
0022
(HEX)
Page 24 PHY Registers
Broadcom
Document AC206-DS05-405-R