AD120
Absolute Maximum Ratings Over Operating Free-air Temperature Range
Parameter
Supply Voltage
Supply Voltage
Supply Voltage
Supply Voltage
Supply Voltage
Input Voltage
Storage Temperature
Symbol
VDD
VH
VL
VOFF
VH - VL
VIN
Tstg
Ratings
Unit
-0.3 ~ +7.0
V
-0.3 ~ 42.0
V
-20.0 ~ +0.3
V
VL-0.3 ~ VL+11.0
V
-0.3 ~ 42.0
V
-0.3 ~ VDD+0.3
V
-55 ~ 125
°C
Power_on Sequence and Voltage Levels
VH
VDD
VSS
Out0~Out257
VDD
Logic Signal VSS
VOFF
VL
Operating Voltage Range
Parameter
Supply Voltage
Supply Voltage
Supply Voltage
Supply Voltage
Supply Voltage
Clock Frequency
Operating Free-air Temperature
Symbol
VDD
VH
VL
VOFF - VL
VH - VL
fCP
Ta
Min.
2.7
17
-15
0
22
-
-20
Typ.
3.3
-
-
-
-
-
-
Max. Unit
3.6
V
28
V
-5
V
10.0
V
40
V
100
KHz
+75
°C
PRELIMINARY (August, 2001, Version 0.0)
8
AMIC Technology, Inc