Temperature Channel ADC Offset Calibration Register
Name: ADC2OF
Address: 0xFFFF0538
Default
Value:
Part specific, factory programmed
Access: Read/write
Function:
This ADC Offset MMR holds a 16-bit offset cali-
bration coefficient for the temperature channel.
The register is configured at power-on with a
factory default value. However, this register is
automatically overwritten if an offset calibration
of the temperature channel is initiated by the user
via bits in the ADCMDE MMR. User code can only
write to this calibration register if the ADC
is in idle mode. An ADC must be enabled and in
idle mode before being written to any offset or
gain register. The ADC must be in idle mode for at
least 23 μs.
Current Channel ADC Gain Calibration Register
Name: ADC0GN
Address: 0xFFFF053C
Default
Value:
Part specific, factory programmed
Access: Read/write
Function:
This gain MMR holds a 16-bit gain calibration
coefficient for scaling the I-ADC conversion result.
The register is configured at power-on with a
factory default value. However, this register is
automatically overwritten if a gain calibration of
the I-ADC is initiated by the user via bits in the
ADCMDE MMR. User code can only write to this
calibration register if the ADC is in idle mode. An
ADC must be enabled and in idle mode before
being written to any offset or gain register. The
ADC must be in idle mode for at least 23 μs.
ADuC7033
Voltage Channel Gain Calibration Register
Name: ADC1GN
Address: 0xFFFF0540
Default
Value:
Part specific, factory programmed
Access: Read/write
Function:
This gain MMR holds a 16-bit gain calibration
coefficient for scaling a voltage channel conversion
result. The register is configured at power-on with
a factory default value. However, this register is
automatically overwritten if a gain calibration of
the voltage channel is initiated by the user via bits
in the ADCMDE MMR. User code can only write
to this calibration register if the ADC is in idle
mode. An ADC must be enabled and in idle mode
before being written to any offset or gain register.
The ADC must be in idle mode for at least 23 μs.
Temperature Channel Gain Calibration Register
Name: ADC2GN
Address: 0xFFFF0544
Default
Value:
Part specific, factory programmed
Access: Read/write
Function:
This gain MMR holds a 16-bit gain calibration
coefficient for scaling a temperature channel
conversion result. The register is configured at
power-on with a factory default value. However,
this register is automatically overwritten if a gain
calibration of the temperature channel is initiated
by the user via bits in the ADCMDE MMR. User
code can only write to this calibration register if the
ADC is in idle mode. An ADC must be enabled
and in idle mode before being written to any offset
or gain register. The ADC must be in idle mode for
at least 23 μs.