Qdatasheet_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

AT80C51RA2-3CSCV View Datasheet(PDF) - International Rectifier

Part Name
Description
MFG CO.
AT80C51RA2-3CSCV
IR
International Rectifier IR
'AT80C51RA2-3CSCV' PDF : 85 Pages View PDF
11. Electrical Characteristics
11.1 Absolute Maximum Ratings
Ambiant Temperature Under Bias:
C = commercial......................................................0°C to 70°C
I = industrial ........................................................-40°C to 85°C
Storage Temperature .................................... -65°C to + 150°C
Voltage on VCC to VSS ........................................-0.5 V to + 7 V
Voltage on Any Pin to VSS........................-0.5 V to VCC + 0.5 V
Power Dissipation .............................................................. 1 W
*NOTICE:
Stresses at or above those listed under “ Abso-
lute Maximum Ratings” may cause permanent
damage to the device. This is a stress rating only
and functional operation of the device at these or
any other conditions above those indicated in the
operational sections of this specification is not
implied. Exposure to absolute maximum rating
conditions may affect device reliability.
Power dissipation is based on the maximum
allowable die temperature and the thermal resis-
tance of the package.
11.2
Power Consumption Measurement
Since the introduction of the first C51 devices, every manufacturer made operating Icc measure-
ments under reset, which made sense for the designs were the CPU was running under reset. In
Atmel new devices, the CPU is no more active during reset, so the power consumption is very
low but is not really representative of what will happen in the customer system. That’s why, while
keeping measurements under Reset, Atmel presents a new way to measure the operating Icc:
Using an internal test ROM, the following code is executed:
Label:
SJMP Label (80 FE)
Ports 1, 2, 3 are disconnected, Port 0 is tied to FFh, EA = Vcc, RST = Vss, XTAL2 is not con-
nected and XTAL1 is driven by the clock.
This is much more representative of the real operating Icc.
11.3
DC Parameters for Standard Voltage
TA = 0°C to +70°C; VSS = 0 V; VCC = 5 V ± 10%; F = 0 to 40 MHz.
TA = -40°C to +85°C; VSS = 0 V; VCC = 5 V ± 10%; F = 0 to 40 MHz.
Table 11-1. DC Parameters in Standard Voltage
Symbol Parameter
Min
Typ
Max
Unit
Test Conditions
VIL
Input Low Voltage
VIH
Input High Voltage except XTAL1, RST
VIH1
Input High Voltage, XTAL1, RST
VOL
Output Low Voltage, ports 1, 2, 3, 4, 5(6)
VOL1
Output Low Voltage, port 0 (6)
VOL2
Output Low Voltage, ALE, PSEN
-0.5
0.2 VCC + 0.9
0.7 VCC
0.2 VCC - 0.1
VCC + 0.5
VCC + 0.5
0.3
0.45
1.0
0.3
0.45
1.0
0.3
0.45
1.0
V
V
V
V IOL = 100 μA(4)
V IOL = 1.6 mA(4)
V IOL = 3.5 mA(4)
V IOL = 200 μA(4)
V IOL = 3.2 mA(4)
V IOL = 7.0 mA(4)
V IOL = 100 μA(4)
V IOL = 1.6 mA(4)
V IOL = 3.5 mA(4)
58 AT/TS8xC51Rx2
4188E–8051–08/06
Share Link: GO URL