LIBERATOR CL10K30A
AC Electrical Specifications cont.
EAB Timing Parameters[5]
Symbol
Parameter
Speed: -1
Min Max
tEABAA EAB Address Access Delay
9.7
tEABRCCOMB EAB Asynchronous Read Cycle Time
9.7
tEABRCREG EAB Synchronous Read Cycle Time
5.9
tEABWP EAB Write Pulse Width
3.8
tEABWCCOMB EAB Asynchronous Write Cycle Time
4.0
tEABWCREG EAB Synchronous Write Cycle Time
9.8
tEABDD EAB Data-in to Data-out Delay
9.2
tEABDATACO
EAB Clock-to-output Delay Using Output
Regis ters
1.7
tEABDATASU
EAB Data/Address Setup Time Using Input
Regis ter
2.3
tEABDATAH
EAB Data/Address Hold Time Using Input
Regis ter
0.0
tEABWESU EAB WE Setup When Using Input Register
3.3
tEABWESH
EAB WE Hold Time When Using Input
Regis ter
0.0
tEABWDSU
EAB Data Setup Time to Falling Edge of
Write Pulse When Not Using Input Registers
3.2
Speed: -2
Min Max
11.6
11.6
7.1
4.5
4.7
11.6
11.0
2.1
2.7
0.0
3.9
0.0
3.8
Speed: -3
Min Max Unit
16.2 ns
16.2
ns
9.7
ns
5.9
ns
6.3
ns
16.6
ns
16.1 ns
3.4
ns
3.5
ns
0.0
ns
4.9
ns
0.0
ns
5.0
ns
tEABWDH
EAB Data Hold Time After Falling Edge of
Write Pulse When Not Using Input Registers
0.0
0.0
0.0
ns
tEABWASU
EAB Address Setup Time to Rising Edge of
Write Pulse When Not Using Input Registers
3.7
4.4
5.1
ns
EAB Address Hold Time After Falling Edge
tEABWAH of Write Pulse When Not Using Input
0.0
0.0
0.0
ns
Regis ters
tEABWO EAB WE to Data Output Delay
6.1
7.3
11.3 ns
10KA tbl 11C