3.2.Definition of Viewing Angle and Optimum Viewing Area
・Point ● shows the point where contrast ratio is measured. : θ= 0 ゚, φ=-゚
・Driving condition : 1/64 Duty, 1/9 Bias, VOD=14.0V, fF=140Hz
90゚
135゚
45゚
180゚
φ
θ
10 20 30 40 50 (φ= 0゚)
θ
180゚
225゚
・Area
270゚
shows typ. CR≧2
315゚
270゚
90゚
φ
0゚
3.3.System Block Diagram
Photometer
#1980A WB
Temperature Chamber
Rotation Table (θ,φ)
φ
LCD
Optical Fiber
θ
Computer
Control Unit &
Waveform Generator
Halogen bulb
F-51168NCU-FW-AA (AA) No.2000-0140
OPTREX CORPORATION
OPTREX
Page 9/18