Status Register Encoding
During the Result Phase of certain commands, the Data Register contains data bytes that give the status of the
command just executed.
Table 28 - Status Register 0
BIT
NO. SYMBOL NAME
DESCRIPTION
7,6 IC
Interrupt 00 - Normal termination of command. The specified command was
Code
properly executed and completed without error.
01 - Abnormal termination of command. Command execution was
started, but was not successfully completed.
10 - Invalid command. The requested command could not be executed.
11 - Abnormal termination caused by Polling.
5 SE
Seek End The FDC completed a Seek, Relative Seek or Recalibrate command
(used during a Sense Interrupt Command).
4 EC
Equipment The TRK0 pin failed to become a “1” after:
Check
1. 80 step pulses in the Recalibrate command.
2. The Relative Seek command caused the FDC to step outward beyond
Track 0.
3
Unused. This bit is always “0”.
2H
Head
The current head address.
Address
1,0 DS1,0 Drive
The current selected drive.
Select
Table 29 - Status Register 1
BIT
NO. SYMBOL NAME
DESCRIPTION
7 EN
End of
The FDC tried to access a sector beyond the final sector of the track
Cylinder (255D). Will be set if TC is not issued after Read or Write Data command.
6
Unused. This bit is always “0”.
5 DE
Data Error The FDC detected a CRC error in either the ID field or the data field of a
sector.
4 OR
Overrun/ Becomes set if the FDC does not receive CPU or DMA service within the
Underrun required time interval, resulting in data overrun or underrun.
3
Unused. This bit is always “0”.
2 ND
No Data Any one of the following:
1. Read Data, Read Deleted Data command - the FDC did not find the
specified sector.
2. Read ID command - the FDC cannot read the ID field without an error.
3. Read A Track command - the FDC cannot find the proper sector
sequence.
1 NW
Not
WP pin became a “1” while the FDC is executing a Write Data, Write
Writable Deleted Data, or Format A Track command.
0 MA
Missing Any one of the following:
Address 1. The FDC did not detect an ID address mark at the specified track after
Mark
encountering the index pulse from the IDX pin twice.
2. The FDC cannot detect a data address mark or a deleted data
address mark on the specified track.
SMSC DS – FDC37N869