Typical Performance Characteristics
Performance characteristics over recommended operating conditions. Typical values at 25°C, VDD = 3.3 V, 18 MHz.
Parameter
Symbol Min. Typ. Max. Units Notes
Path Error (Deviation) PError
0.5
%
Path Error (Deviation) is the error from the ideal cursor path. It is expressed
as a percentage of total travel and is measured over standard surfaces.
The following graphs (Figs 20–23)
are the typical performance of
the ADNS-2030 sensor, assembled
as shown in the 2D assembly
drawing with the HDNS-2100
Lens/Prism, the HDNS-2200 clip,
and the HLMP-ED80-XXXXX LED
(See Figure 5).
450
350
Z
DOF
250
DOF
Recommended
Operating
150
Region
white paper
manila folder
50
burl formica
dark walnut
black copy
-50
1.5 1.9 2.3 2.7 3.1 3.5
HEIGHT, Z (mm)
(2.4 = nominal focus)
Figure 20. Typical Resolution vs. Height, Z.
(Comparative Surfaces)
1.0
0.8
0.6
0.4
0.2
0
400 500 600 700 800 900 1000
WAVELENGTH (nm)
Figure 21. Wavelength Responsivity[1].
450
400
350
Z
300
DOF
250
DOF
Recommended
200
Operating
Region
150
100
100%
75%
50
50%
0
1.5 1.9 2.3 2.7 3.1 3.5
HEIGHT, Z (mm)
(2.4 = nominal focus)
Figure 22. Typical Resolution vs. Height, Z.
(Manila folder and LED variation)[2,3]
450
400
350
300
250
200
Z
DOF
150
DOF
Recommended
100
Operating
Region
50
100%
0
75%
50%
-50
1.5 1.9 2.3 2.7 3.1 3.5
HEIGHT, Z (mm)
(2.4 = nominal focus)
Figure 23. Typical Resolution vs. Height, Z.
(Black copy and LED variation)[2,3]
Notes :
1. The ADNS-2030 is designed for optimal performance when used with the HLMP-ED80-XXXXX
(Red LED 639nm). For use with other LED colors (ie. blue, green), please consult factory. When
using alternate LED’s there may also be performance degradation and additional eye safety
consideration.
2. Z = Distance from Lens Reference Plane to Surface.
3. DOF = Depth of Field
15