FUM00701
21
Table 6. Identifier Codes and OTP Address for Read Operation
Code
Address
[A15-A0](1)
Data
[DQ15-DQ0]
Notes
Manufacturer Code
Manufacturer Code
0000H
00B0H
Device Code
(32M-bit device)
32M Top Parameter Device Code
32M Bottom Parameter Device Code
0001H
0001H
00B4H
2
00B5H
3
Device Code
(64M-bit device)
64M Top Parameter Device Code
64M Bottom Parameter Device Code
0001H
0001H
00B0H
2
00B1H
3
Block Lock Configuration Block is Unlocked
Code
Block is Locked
Block is not Locked-Down
Block is Locked-Down
DQ0 = 0
4
Block
DQ0 = 1
4
Address
+2
DQ1 = 0
4
DQ1 = 1
4
Device Configuration Code Read Configuration Register
0005H
RCRC
5
Partition Configuration Register
0006H
PCRC
6
OTP
OTP Lock
0080H
OTP-LK
7
OTP
0081-0088H
OTP
8
NOTES:
1. The address A20-A16 to read the manufacturer, device, lock configuration, device configuration code and OTP data are
shown in below table.
2. Top parameter device has its parameter blocks in the plane3 (The highest address).
3. Bottom parameter device has its parameter blocks in the plane0 (The lowest address)
4. DQ15-DQ2 is reserved for future implementation.
5. RCRC=Read Configuration Register Code.
6. PCRC=Partition Configuration Register Code.
7. OTP-LK=OTP Block Lock configuration.
8. OTP=OTP Block data.
Table 7. Identifier Codes and OTP Address for Read Operation on Partition Configuration(1) for 32M-bit device
Partition Configuration Register
Address (32M-bit device)
PCR.10
PCR.9
PCR.8
[A20-A16]
0
0
0
00H
0
0
1
00H or 08H
0
1
0
00H or 10H
1
0
0
00H or 18H
0
1
1
00H or 08H or 10H
1
1
0
00H or 10H or 18H
1
0
1
00H or 08H or 18H
1
1
1
00H or 08H or 10H or 18H
NOTES:
1. The address to read the identifier codes or OTP data is dependent on the partition which is selected when writing the Read
Identifier Codes/OTP command (90H).
Synchronous burst mode will be available for future device.
Appendix to Spec No.: MFM2-J13207 Model No.: LRS1383 March 1, 2001
Rev. 2.20