Maximum rating
9
Maximum rating
M25P128
Stressing the device outside the ratings listed in Table 9 may cause permanent damage to
the device. These are stress ratings only, and operation of the device at these, or any other
conditions outside those indicated in the Operating sections of this specification, is not
implied. Exposure to Absolute Maximum Rating conditions for extended periods may affect
device reliability. Refer also to the Numonyx SURE Program and other relevant quality
documents.
Table 9.
Symbol
Absolute maximum ratings
Parameter
TSTG Storage Temperature
VIO Input and output voltage (with respect to Ground)
VCC Supply voltage
VPP
VESD
Fast Program/Erase voltage
Electrostatic Discharge Voltage (Human Body Model) (1)
1. JEDEC Std JESD22-A114A (C1=100 pF, R1=1500 Ω, R2=500 Ω)
Min.
Max. Unit
–65
150
°C
–0.5 VCC + 0.6 V
–0.2
4.0
V
–0.2
10.0
V
–2000 2000
V
34/45