NXP Semiconductors
PCA9519
4-channel level translating I2C-bus/SMBus repeater
HIGH. It is important to note that any arbitration or clock stretching events require that the
LOW level on the port A bus at the input of the PCA9519 (VIL) is below VILc to be
recognized by the PCA9519 and then transmitted to the port B bus.
9th clock pulse
acknowledge
SCL
SDA
Fig 5. Bus B SMBus/I2C-bus waveform
002aab644
SCL
SDA
9th clock pulse
acknowledge
VOL of master
Fig 6. Bus A lower voltage waveform
8. Limiting values
Table 4. Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134).
Symbol
Parameter
Conditions
VCC(B)
VCC(A)
VI/O
supply voltage port B
supply voltage port A
voltage on an input/output pin
port A
port B; enable pin (EN)
II/O
II
Ptot
Tstg
Tamb
Tj
Tsp
input/output current
input current
total power dissipation
storage temperature
ambient temperature
junction temperature
solder point temperature
operating in free air
10 s max.
VOL of PCA9519
002aab645
Min
Max
Unit
0.5
+6
V
0.5
+6
V
0.5
+6
V
0.5
+6
V
-
20
mA
-
20
mA
-
100
mW
65
+150
C
40
+85
C
-
125
C
-
300
C
PCA9519
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 3 — 10 January 2013
© NXP B.V. 2013. All rights reserved.
7 of 21