NXP Semiconductors
PCF2129T
Accurate RTC with integrated quartz crystal for industrial
8.11.4 Dependency between Battery switch-over and timestamp
The timestamp function depends on the control bit BTSE in register Control_3:
Table 45. Battery switch-over and timestamp
BTSE BF
Description
0
-
[1] the battery switch-over does not affect the timestamp registers
1
If a battery switch-over event occurs:
0
[1] the timestamp registers store the time and date when the switch-over occurs;
after this event occurred BF is set logic 1
1
the timestamp registers are not modified;
in this condition subsequent battery switch-over events or falling edges on pin
TS are not registered
[1] Default value.
PCF2129T
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 3 — 12 February 2013
© NXP B.V. 2013. All rights reserved.