STV9432TAP
10 - DIGITAL TO ANALOG PWM OUTPUTS
The five to A outputs PWM1 toc5 of the STV9432TAP are pulse width modulator type converter outputs.
The frequency of the output signal is fOSC: 256 and the duty cycle is: Value [7:0]: 256. After an external
low pass filter, the voltage value of the output is: Value [7:0] x VDD : 256.
Figure 8.
PWM1 Signal
V1[7:0]
0
tOSC
256 x tOSC
1
128
255
10.1 - PWM REGISTERS
Pulse Width Modulator 1
4038
V17
V16
V15
V14
V13
V12
V11
V10
V1[7:0] : Digital value of the 1st PWM D to A converter (Pin 13)
Pulse Width Modulator 2
4039
V27
V26
V25
V24
V23
V22
V21
V20
V2[7:0] : Digital value of the 2nd PWM D to A converter (Pin 14)
Pulse Width Modulator 3
403A
V37
V36
V35
V34
V33
V32
V31
V30
V3[7:0] : Digital value of the 3rd PWM D to A converter (Pin 15)
Pulse Width Modulator 4
403B
V47
V46
V45
V44
V43
V42
V41
V40
V4[7:0] : Digital value of the 4th PWM D to A converter (Pin 16)
Pulse Width Modulator 5
403C
V57
V56
V55
V54
V53
V52
V51
V50
V5[7:0] : Digital value of the 5th PWM D to A converter (Pin 17)
Note: Power-on reset default value of PWM register is OOH.
14/25