Table 1. IEC/EN/DIN EN 60747-5-5 Insulation Characteristics*
Description
Symbol
Characteristic Unit
Installation classification per DIN VDE 0110/39, Table 1
for rated mains voltage ≤ 150 VRMS
for rated mains voltage ≤ 300 VRMS
for rated mains voltage ≤ 600 VRMS
for rated mains voltage ≤ 1000 VRMS
I – IV
I – IV
I – IV
I – III
Climatic Classification
40/105/21
Pollution Degree (DIN VDE 0110/39)
2
Maximum Working Insulation Voltage
VIORM
1414
Vpeak
Input to Output Test Voltage, Method b**
VPR
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec, Partial discharge < 5 pC
2652
Vpeak
Input to Output Test Voltage, Method a**
VIORM x 1.6 = VPR, Type and Sample Test, tm = 10 sec, Partial discharge < 5 pC
VPR
2262
Vpeak
Highest Allowable Overvoltage (Transient Overvoltage tini = 60 sec)
VIOTM
8000
Vpeak
Safety-limiting values – maximum values allowed in the event of a failure.
Case Temperature
TS
175
°C
Input Current
IS, INPUT
400
mA
Output Power
PS, OUTPUT 1200
mW
Insulation Resistance at TS, VIO = 500 V
RS
>109
W
* Isolation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits in application.
Surface mount classification is class A in accordance with CECCOO802.
** Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section IEC/EN/
DIN EN 60747-5-5, for a detailed description of Method a and Method b partial discharge test profiles.
Table 2. Insulation and Safety Related Specifications
Parameter
Minimum External Air Gap
(Clearance)
Minimum External Tracking
(Creepage)
Minimum Internal Plastic Gap
(Internal Clearance)
Symbol
L(101)
L(102)
ACPL-336J
8.3
8.3
0.5
Tracking Resistance
CTI
(Comparative Tracking Index)
Isolation Group
>175
IIIa
Units
mm
mm
mm
V
Conditions
Measured from input terminals to output terminals,
shortest distance through air.
Measured from input terminals to output terminals,
shortest distance path along body.
Through insulation distance conductor to conductor,
usually the straight line distance thickness between the
emitter and detector.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
4