Table 7. Package Characteristics
Parameter
Symbol Min. Typ. Max. Units Test Conditions
Note
Input-Output Momentary
Withstand Voltage
Resistance (Input-Output)
VISO
5000
RI-O
> 109
VRMS
W
RH < 50%,
1, 2, 3
t = 1 min., TA = 25 °C
VI-O = 500 VDC
3
Capacitance (Input-Output)
CI-O
1.3
pF
freq =1 MHz
Thermal Coefficient Between
4
LED and Input IC
AEI
LED and Output IC
AEO
Input IC and Output IC
AIO
LED and Ambient
AEA
Input IC and Ambient
AIA
Output IC and Ambient
AOA
35.4
33.1
25.6
176.1
92
76.7
°C/W
°C/W
°C/W
°C/W
°C/W
°C/W
Notes
1. In accordance with UL1577, each optocoupler is proof tested by applying an insulation test voltage ≥ 6000 VRMS for 1 second. This test is performed
before the 100% production test for partial discharge (method b) shown in IEC/EN/DIN EN 60747-5-5 Insulation Characteristic Table, if applicable.
2. The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous voltage
rating. For the continuous voltage rating, refer to your equipment level safety specification or IEC/EN/DIN EN 60747-5-5 Insulation Characteristics
Table.
3. Device considered a two-terminal device: pins 1 to 8 are shorted together and pins 9 to 16 are shorted together.
4. For further details, see thermal calculation section in the application notes.
3.5
3.4 IF = 10 mA for ICC1H
3.3
IF = 0 mA for I CC1L
VCC = 30 V
3.2 VEE= 0 V
3.1
3.0
2.9
2.8
2.7
2.6
2.5
-40 -20
0 20 40 60
TA - TEMPERATURE - °C
Figure 1. ICC1 vs. temperature
ICC1L
ICC1H
80 100
7.0
6.5
IF = 10 mA for I CC2H
IF = 0 mA for ICC2L
6.0
VCC = 30 V
VEE = 0 V
5.5
5.0
4.5
4.0
3.5
3.0
-40 -20 0 20 40 60
TA - TEMPERATURE - °C
Figure 2. ICC2 vs. temperature
ICC2L
ICC2H
80 100
7.0
100
6.5
IF = 10 mA for ICC2H
IF = 10 mA for ICC2L
6.0 TA = 25°C
VEE = 0 V
5.5
5.0
10
4.5
4.0
3.5
ICC2L
ICC2H
3.0
1
15
17
19
21
23
25
1.4
VCC - SUPPLY VOLTAGE - V
1.5
1.6
1.7
1.8
VF - LED1 FORWARD VOLTAGE - V
Figure 3. ICC vs.VCC
Figure 4. LED1 Input Current vs. forward voltage