Standard multi-protocol reader solution
Automatic calibration can be set-up to execute at the end of each Transceive command if
bit ClkQCalib = logic 0. Setting bit ClkQCalib = logic 1 disables all automatic calibrations
except after the reset sequence. Automatic calibration can also be triggered by the
software when bit ClkQCalib has a logic 0 to logic 1 transition.
calibration impulse
from reset sequence
calibration impulse
from end of
Transceive command
a rising edge initiates
Q-clock calibration
ClkQCalib bit
001aak616
Fig 13. Automatic Q-clock calibration
Remark: The duration of the automatic Q-clock calibration is 65 oscillator periods or
approximately 4.8 s.
The ClockQControl register’s ClkQDelay[4:0] value is proportional to the phase-shift
between the Q-clock and the I-clock. The ClkQ180Deg status flag bit is set when the
phase-shift between the Q-clock and the I-clock is greater than 180.
Remark:
The StartUp configuration file enables automatic Q-clock calibration after a reset
If bit ClkQCalib = logic 1, automatic calibration is not performed. Leaving this bit set to
logic 1 can be used to permanently disable automatic calibration.
It is possible to write data to the ClkQDelay[4:0] bits using the microprocessor. The
aim could be to disable automatic calibration and set the delay using the software.
Configuring the delay value using the software requires bit ClkQCalib to have been
previously set to logic 1 and a time interval of at least 4.8 s has elapsed. Each delay
value must be written with bit ClkQCalib set to logic 1. If bit ClkQCalib is logic 0, the
configured delay value is overwritten by the next automatic calibration interval.
9.10.2.2 Amplifier
The demodulated signal must be amplified by the variable amplifier to achieve the best
performance. The gain of the amplifiers can be adjusted using the RxControl1 register
Gain[1:0] bits; see Table 29.
Table 29. Gain factors for the internal amplifier
See Table 86 “RxControl1 register bit descriptions” on page 64 for additional information.
Register setting
Gain factor [dB]
(simulation results)
00
20
01
24
10
31
11
35
CLRC632
Product data sheet
COMPANY PUBLIC
All information provided in this document is subject to legal disclaimers.
Rev. 3.7 — 27 February 2014
073937
© NXP Semiconductors N.V. 2014. All rights reserved.
36 of 127
Share Link: GO URL

All Rights Reserved © qdatasheet.com  [ Privacy Policy ] [ Contact Us ]