CY8C20110, CY8C20180
CY8C20160, CY8C20140
CY8C20142
Table 20. CapSense Express CY8C20140/142/160/180/1A0 Errata Summary (continued)
Item
Issues
3
Data Filtering
Description
Fix Status
Addition of two on-chip filtering algorithms for improved Averaging Filter
CapSense performance and better noise immunity. This smoothens the raw count data, and
results in better noise immunity and
performance. The filter can average 2, 4, 8,
or 16 samples.
Drop the Sample Filter
This discards any acquired CapSense
sample if an I2C communication occurs after
the scan process has already started.
For more information on filtering, refer to
application note AN48430 “CapSense
Express-Noise Filtering Methods”.
4
Save to Flash
Save to flash command fails when the sleep interval is No fix will be provided. When using save to
set to 512 or 64 Hz.
flash follow these steps:
1. Write configuration data to registers with
sleep interval set to 8 or 1 Hz
2. Save the settings to flash
3. Change the sleep interval settings per
design
5
False Triggering Dur-
ing Power-Up
If a finger is on the sensor during power-up the sensor
triggers and the baseline gets stuck. This only happens
No fix will be provided. Disable the Averaging
Filter if your design requires a finger on the
when the Averaging Filter is enabled.
sensor during power-up.
Document Number: 001-54606 Rev. *J