Qdatasheet_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

E6F-AG5C-C7202M View Datasheet(PDF) - OMRON Corporation

Part Name
Description
MFG CO.
E6F-AG5C-C7202M
Omron
OMRON Corporation Omron
'E6F-AG5C-C7202M' PDF : 32 Pages View PDF
Operation (Run Mode)
Starting Operation
Set the mode switch to RUN to start operation.
Mode
PRGM
TEST
RUN
12
Start input
indication
(See note.)
7
RUN
Present angular position
CAM
STEP
Speed (r/min)
Note: For 16/32-output models, be sure that the start input is ON
and that the start input indicator is lit. Outputs (including
the cam, pulse, and run outputs) will not function if the
start input is OFF. The 8-output models do not have a
start input.
Switching the Angle and Speed Displays
Press the ON↑ ↓OFF Key for at least 1 s in Run Mode to reverse the
display positions of the present angular position and speed (r/min)
between main display and sub-display.
12
7
RUN
Present angular position on main display
Speed (r/min) on sub-display
Press the ON↑ ↓OFF Key for 1 s min.
12
7
RUN
Speed (r/min) on main display
Present angular position on sub-display
H8PS
All Protection Function
The all protection function locks the H8PS in Run Mode and prohibits
any changes to settings. It can be used to prevent incorrect or
unauthorized operation. If the ADV Key is pressed for at least 5 s in
Run Mode, the All Protection indicator
will light on the display
and all keys and switches will be disabled. If the mode switch is
changed to Programming or Test Mode while protection is enabled,
the All Protection indicator
will flash to indicate that settings
cannot be changed. If a setting on the DIP switch is changed while
protection is enabled, the All Protection indicator
will flash when
the power supply is turned ON to indicate that settings cannot be
changed.
All Protection Function Disabled (Normal Operation)
12
456
RUN
CAM
STEP
Press the ADV Key for 5 s min.
All Protection Function Enabled
12
456
RUN
All protection indication
CAM
STEP
Checking ON/OFF Angle Settings
During Run Mode, the CAM Keys
and STEP Keys
can be used to check the ON/OFF angle settings for any step. Also,
the CHECK Key can be pressed to check the ON/OFF angle
settings in order for all steps starting from cam 1. If there is no key
operation for 10 s or longer during the checking operation, the
previous display will be resumed.
24
Share Link: GO URL

All Rights Reserved © qdatasheet.com  [ Privacy Policy ] [ Contact Us ]