H8PS
Advanced Functions
Set the advanced functions as required to perform more advanced operation. Outlines of the advanced functions are provided on the following
pages. For details, refer to the Operation Manual (Cat. No. Z199).
Mode Transitions
PRGM
TEST
RUN
PRGM
TEST
RUN
PRGM
TEST
RUN
Programming Mode PRG
Changed with the mode switch.
Test Mode
TST
Changed with the mode switch.
Run Mode
RUN
ADV Key 3 s min.
ADV Key 5 s min.
ON/OFF Key 1 s min.
ADV Key
All Protection
Disables all keys
and switches.
will light when the all
protection function is
enabled.
Refer to page 24.
Switching the Angle
and Speed Display
Main Display: Angle
Sub-display: Speed
↓↑
Main Display: Speed
Sub-display: Angle
Refer to page 24.
Setting the
ADV Function
Advance angle
compensation (ADV)
function automatically
advances the ON/OFF
angle of outputs in
proportion to the
machine (Encoder)
speed.
The values in parentheses are the default settings.
Function Setting Mode
Refer to pages 28 to 30.
: No. of pulse outputs [60]
ADV Key
: Pulse output start angle [0°]
ADV Key
: Speed alarm upper limit [---]
ADV Key
: Speed alarm lower limit [---]
ADV Key
: Step number limit [---] (See note 1.)
ADV Key
: Cam protection [None]
ADV Key
: Bank enable/disable [Disable]
ADV Key
: Bank switching method [Bank inputs] (See note 2.)
ADV Key
: Bank copy (See note 2.)
ADV Key
: E24 detection enable/disable [Enable]
ADV Key
Shaded items above are not displayed for 8-output models.
Note 1: The default setting is for 10 steps for all cams.
Note 2: Not displayed when F7 is disabled.
26