LHF80J21
30
6.2.2 AC Input/Output Test Conditions
2.7
INPUT
1.35
TEST POINTS
1.35 OUTPUT
0.0
AC test inputs are driven at 2.7V for a Logic "1" and 0.0V for a Logic "0". Input timing begins, and output timing ends, at 1.35V.
Input rise and fall times (10% to 90%) <10 ns.
Figure 14. Transient Input/Output Reference Waveform for VCC=2.7V-3.6V
1.3V
1N914
Test Configuration Capacitance Loading Value
Test Configuration
VCC=2.7V-3.6V
CL(pF)
50
DEVICE
UNDER
TEST
CL Includes Jig
Capacitance
RL=3.3kΩ
OUT
CL
Figure 15. Transient Equivalent Testing Load Circuit
Rev. 1.27