6. The Modem Control output pins are forced inactive high.
7. Data that is transmitted is immediately received.
This feature allows the processor to verify the transmit and receive data paths of the Serial Port. In the
diagnostic mode, the receiver and the transmitter interrupts are fully operational. The MODEM Control
Interrupts are also operational but the interrupts' sources are now the lower four bits of the MODEM Control
Register instead of the MODEM Control inputs. The interrupts are still controlled by the Interrupt Enable
Register.
Bits 5 through 7
These bits are permanently set to logic zero.
Line Status Register (LSR)
Address Offset = 5H, DLAB = X, READ/WRITE
Bit 0
Data Ready (DR). It is set to a logic "1" whenever a complete incoming character has been received and
transferred into the Receiver Buffer Register or the FIFO. Bit 0 is reset to a logic "0" by reading all of the
data in the Receive Buffer Register or the FIFO.
Bit 1
Overrun Error (OE). Bit 1 indicates that data in the Receiver Buffer Register was not read before the next
character was transferred into the register, thereby destroying the previous character. In FIFO mode, an
overrunn error will occur only when the FIFO is full and the next character has been completely received in
the shift register, the character in the shift register is overwritten but not transferred to the FIFO. The OE
indicator is set to a logic "1" immediately upon detection of an overrun condition, and reset whenever the
Line Status Register is read.
Bit 2
Parity Error (PE). Bit 2 indicates that the received data character does not have the correct even or odd
parity, as selected by the even parity select bit. The PE is set to a logic "1" upon detection of a parity error
and is reset to a logic "0" whenever the Line Status Register is read. In the FIFO mode this error is
associated with the particular character in the FIFO it applies to. This error is indicated when the
associated character is at the top of the FIFO.
Bit 3
Framing Error (FE). Bit 3 indicates that the received character did not have a valid stop bit. Bit 3 is set to a
logic "1" whenever the stop bit following the last data bit or parity bit is detected as a zero bit (Spacing
level). The FE is reset to a logic "0" whenever the Line Status Register is read. In the FIFO mode this
error is associated with the particular character in the FIFO it applies to. This error is indicated when the
associated character is at the top of the FIFO. The Serial Port will try to resynchronize after a framing error.
To do this, it assumes that the framing error was due to the next start bit, so it samples this 'start' bit twice
and then takes in the 'data'.