DC and AC parameters
7
DC and AC parameters
M34C02-W, M34C02-L, M34C02-R
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC Characteristic tables that
follow are derived from tests performed under the Measurement Conditions summarized in
the relevant tables. Designers should check that the operating conditions in their circuit
match the measurement conditions when relying on the quoted parameters.
Table 6. Operating Conditions (M34C02-W)
Symbol
Parameter
Min.
Max.
VCC Supply Voltage
TA
Ambient Operating Temperature
2.5
5.5
–40
85
Table 7. Operating Conditions (M34C02-L)
Symbol
Parameter
VCC
Supply Voltage
TA
Ambient Operating Temperature
Min.
2.2
–40
Max.
5.5
85
Table 8. Operating Conditions (M34C02-R)
Symbol
Parameter
Min.
Max.
VCC Supply Voltage
TA
Ambient Operating Temperature
1.8
5.5
–40
85
Table 9. AC Measurement Conditions
Symbol
Parameter
CL
Load Capacitance
Input Rise and Fall Times
Input Levels
Input and Output Timing Reference Levels
Min.
Max.
100
50
0.2VCC to 0.8VCC
0.3VCC to 0.7VCC
Figure 12. AC Measurement I/O Waveform
Input Levels
0.8VCC
0.2VCC
Input and Output
Timing Reference Levels
0.7VCC
0.3VCC
AI00825B
Unit
V
°C
Unit
V
°C
Unit
V
°C
Unit
pF
ns
V
V
22/31