DC and AC parameters
9
DC and AC parameters
M95320-W M95320-R M95320-DR
This section summarizes the operating conditions and the DC/AC characteristics of the
device.
Table 9. Operating conditions (M95320-W, device grade 6)
Symbol
Parameter
Min.
Max.
Unit
VCC Supply voltage
TA
Ambient operating temperature
2.5
5.5
V
–40
85
°C
Table 10. Operating conditions (M95320-R and M95320-DR, device grade 6)
Symbol
Parameter
Min.
Max.
Unit
VCC
Supply voltage
TA
Ambient operating temperature
1.8
5.5
V
–40
85
°C
Table 11. AC measurement conditions
Symbol
Parameter
CL
Load capacitance
Input rise and fall times
Input pulse voltages
Input and output timing reference voltages
Min.
Max.
30
25
0.2 VCC to 0.8 VCC
0.3 VCC to 0.7 VCC
Unit
pF
ns
V
V
Figure 18. AC measurement I/O waveform
)NPUT VOLTAGE LEVELS
6##
6##
)NPUT AND OUTPUT
TIMING REFERENCE LEVELS
6##
6##
!)#
32/48